3HAC028357-001 DSQC679 ABB Pressure Transmitter Operation Manual
1. Product Overview
The CVC750AE101 is a high-precision pressure transmitter with 0.25% accuracy, designed for industrial applications requiring 0-400 bar measurement range. Key features include:
- Output Signal: 4-20 mA (2-wire system)
- Power Supply: 12-42 VDC (reverse polarity protection)
- Environmental Rating: IP65 enclosure for dust/moisture resistance

2. Installation Procedures
2.1 Mechanical Mounting
- Secure the transmitter to the measurement point using M20×1.5 threaded connection (torque ≤ 50 N·m).
- Avoid mounting near vibration sources or high-temperature zones (>85°C).
2.2 Electrical Wiring
- Power/Output: Connect to terminal blocks as follows:
+V (Pin 1) —— 24V DC+ -V (Pin 2) —— 24V DC- OUT+ (Pin 3) —— 4-20mA+ OUT- (Pin 4) —— 4-20mA- - Shielding: Ground the cable shield at one end only (recommended at control panel side)
3. Calibration & Verification
3.1 Zero/Span Adjustment
- Use the calibration screw with a 2.5mm hex key:
- Zero: Apply 0 bar pressure, adjust until output reads 4.00±0.02 mA
- Span: Apply 400 bar pressure, adjust until output reads 20.00±0.05 mA
3.2 Functional Test
- Perform step pressure test (0%/50%/100% range) and verify:
| Pressure | Expected Output | Tolerance | |----------|-----------------|-----------| | 0 bar | 4.00 mA | ±0.1 mA | | 200 bar | 12.00 mA | ±0.15 mA | | 400 bar | 20.00 mA | ±0.1 mA |
4. Maintenance & Troubleshooting
- Routine Check: Monthly inspection for:
- Cable integrity (no abrasion/corrosion)
- Connector tightness (retorque to 0.5 N·m if loose)
- Error Codes:
- LED Red Blinking: Check power polarity (possible reverse connection)
- Output Drift: Recalibrate or replace if deviation exceeds ±0.5% FS

5. Safety Compliance
- Complies with EN 61010-1 (Electrical Safety) and EN 61326-1 (EMC Immunity)
- Hazardous area installations require ATEX/IECEx certification (optional).